Search results for "Prosthesis Implantation"

showing 10 items of 200 documents

CT angiography for the assessment of EVAR complications : a pictorial review

2022

Aortic aneurysm; Blood vessel prosthesis implantation; Endovascular procedures Aneurisma aórtico; Implantación de prótesis de vasos sanguíneos; Procedimientos endovasculares Aneurisma aòrtic; Implantació de pròtesis de vasos sanguinis; Procediments endovasculars Endovascular aneurysm repair (EVAR) is a minimally invasive treatment proposed as an alternative to open repair in patients with abdominal aortic aneurysms. EVAR consists in a stent-graft placement within the aorta in order to exclude the aneurysm from arterial circulation and reduce the risk of rupture. Knowledge of the various types of devices is mandatory because some stents/grafts are more frequently associated with complication…

:intervenciones quirúrgicas::procedimientos quirúrgicos cardiovasculares::procedimientos quirúrgicos vasculares::procedimientos endovasculares [TÉCNICAS Y EQUIPOS ANALÍTICOS DIAGNÓSTICOS Y TERAPÉUTICOS]:Cardiovascular Diseases::Vascular Diseases::Aneurysm::Aortic Aneurysm::Aortic Aneurysm Abdominal [DISEASES]Aortic aneurysmR895-920:diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::interpretación de imágenes asistida por ordenador::tomografía computarizada por rayos X::angiografía por tomografía computarizada [TÉCNICAS Y EQUIPOS ANALÍTICOS DIAGNÓSTICOS Y TERAPÉUTICOS]:Otros calificadores::Otros calificadores::/diagnóstico por imagen [Otros calificadores]:enfermedades cardiovasculares::enfermedades vasculares::aneurisma::aneurisma de la aorta::aneurisma de la aorta abdominal [ENFERMEDADES]Blood vessel prosthesis implantation:Surgical Procedures Operative::Cardiovascular Surgical Procedures::Vascular Surgical Procedures::Endovascular Procedures [ANALYTICAL DIAGNOSTIC AND THERAPEUTIC TECHNIQUES AND EQUIPMENT]Medical physics. Medical radiology. Nuclear medicineVasos sanguinis - CirurgiaEndovascular procedureEndovascular procedures:Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Image Interpretation Computer-Assisted::Tomography X-Ray Computed::Computed Tomography Angiography [ANALYTICAL DIAGNOSTIC AND THERAPEUTIC TECHNIQUES AND EQUIPMENT]cardiovascular systemRadiology Nuclear Medicine and imagingAbdominalStentsAngiografiacardiovascular diseasesComputed tomography angiography:Other subheadings::Other subheadings::/diagnostic imaging [Other subheadings]Educational ReviewAneurisma abdominal - Imatgeria
researchProduct

Evaluation of the stromal vascular fraction of adipose tissue as the basis for a stem cell-based tissue-engineered vascular graft

2017

Abstract Objective One of the rate-limiting barriers within the field of vascular tissue engineering is the lengthy fabrication time associated with expanding appropriate cell types in culture. One particularly attractive cell type for this purpose is the adipose-derived mesenchymal stem cell (AD-MSC), which is abundant and easily harvested from liposuction procedures. Even this cell type has its drawbacks, however, including the required culture period for expansion, which could pose risks of cellular transformation or contamination. Eliminating culture entirely would be ideal to avoid these concerns. In this study, we used the raw population of cells obtained after digestion of human lipo…

Adult0301 basic medicinePathologymedicine.medical_specialtyTime FactorsCellular differentiationMyocytes Smooth MusclePopulationAdipose tissueCell Separation030204 cardiovascular system & hematologyMesenchymal Stem Cell TransplantationMuscle Smooth VascularArticleBlood Vessel Prosthesis Implantation03 medical and health sciences0302 clinical medicineLipectomyCell MovementBlood vessel prosthesisAnimalsHumansMedicineAorta AbdominaleducationCells CulturedBioprosthesiseducation.field_of_studyTissue EngineeringTissue Scaffoldsbusiness.industryAngiotensin IIMesenchymal stem cellCell DifferentiationMesenchymal Stem CellsAnatomyStromal vascular fractionAngiotensin IIBlood Vessel ProsthesisPhenotype030104 developmental biologyAdipose TissueRats Inbred LewFemaleSurgeryStromal CellsStem cellbusinessCardiology and Cardiovascular Medicine
researchProduct

Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair

2015

Endografts placed in the aorta for thoracic endovascular aortic repair (TEVAR) may determine malappositioning to the lesser curvature of the aortic wall, thus resulting in a devastating complication known as endograft collapse. This premature device failure commonly occurs in young individuals after TEVAR for traumatic aortic injuries as a result of applications outside the physical conditions for which the endograft was designed. In this study, an experimentally-calibrated fluid-structure interaction (FSI) model was developed to assess the hemodynamic and stress/strain distributions acting on the excessive protrusion extension (PE) of endografts deployed in four young patients underwent TE…

AdultMaleAortic archmedicine.medical_specialtyHemodynamicsAorta ThoracicHealth InformaticsProsthesis DesignBlood Vessel Prosthesis ImplantationYoung AdultAortic aneurysmBlood vessel prosthesismedicine.arteryInternal medicineFluid-structure interactionStentHumansMedicineThoracic aortaStent-graftHemodynamicEndovascular ProcedureAortaAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresHemodynamicsmedicine.diseaseCurvatures of the stomachBlood Vessel ProsthesisComputer Science ApplicationsSurgeryAlgorithmRadiographyDescending aortaCalibrationCardiologyEndograft collapse/infoldingStentsStress MechanicalThoracic endovascular aortic repair (TEVAR)businessAlgorithmsBird-beakHumanComputers in Biology and Medicine
researchProduct

Skull Bone Defects Reconstruction with Custom-Made Titanium Graft shaped with Electron Beam Melting Technology: Preliminary Experience in a Series of…

2017

Background: Cranioplasty represents a challenge in neurosurgery. Its goal is not only plastic reconstruction of the skull but also to restore and preserve cranial function, to improve cerebral hemodynamics, and to provide mechanical protection of the neural structures. The ideal material for the reconstructive procedures and the surgical timing are still controversial. Many alloplastic materials are available for performing cranioplasty and among these, titanium still represents a widely proven and accepted choice. Methods: The aim of our study was to present our preliminary experience with a “custom-made” cranioplasty, using electron beam melting (EBM) technology, in a series of ten patien…

AdultMaleDecompressive Craniectomymedicine.medical_treatmentchemistry.chemical_elementDentistryNeurosurgical ProceduresCranioplasty030218 nuclear medicine & medical imagingProsthesis Implantation03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineFreezingElectron beam melting technologymedicineHumansSkull boneReconstructive Surgical ProceduresCustom-made titanium implantsAgedRetrospective StudiesTitaniumSettore MED/27 - Neurochirurgiabusiness.industrySkullMiddle AgedCranioplastySkullmedicine.anatomical_structurechemistry3D computer-aided design and computer-aided manufacturing (CAD/CAM) technologiesCerebral hemodynamicsComputer-Aided DesignFemaleSkull bone defectsTomography X-Ray Computedbusiness030217 neurology & neurosurgeryTitaniumBiomedical engineering
researchProduct

Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes

2019

Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…

AdultMaleKeratoconusIntraocular pressuremedicine.medical_specialtygenetic structuresContact LensesCorneal StromaKeratoconusEndothelial cell countCorneaProsthesis ImplantationCorneoscleral contact lensCorneal hysteresisTonometry OcularYoung Adult03 medical and health sciences0302 clinical medicineProsthesis FittingCorneaOphthalmologyHumansMedicineProspective StudiesIntracorneal ring segmentIntraocular Pressurebusiness.industryHealthy subjectsProstheses and Implantsmedicine.diseaseElasticityeye diseasesBiomechanical PhenomenaOphthalmologyCross-Sectional Studiesmedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsbusiness030217 neurology & neurosurgeryEye & Contact Lens: Science & Clinical Practice
researchProduct

Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.

2012

To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …

AdultMaleKeratoconusmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentCorneal StromaVision DisordersVisual AcuityComa (optics)Power vectorKeratoconusRefraction OcularCohort StudiesProsthesis ImplantationYoung AdultOphthalmologymedicineHumansPolymethyl MethacrylateProspective StudiesAlpins methodAgedIntrastromal corneal ring segmentbusiness.industryCorneal TopographyProstheses and ImplantsMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologySurgeryFemalesense organsLaser TherapyCorneal ringbusinessJournal of cataract and refractive surgery
researchProduct

Questionable Value of Adjuvant Arteriovenous Fistula in Pedal Bypass at High Risk for Early Failure

2007

Results of an adjuvant arteriovenous fistula (AVF) in pedal bypass surgery in the presence of poor status of the recipient artery, severely impaired intraoperative runoff, or revision for early failure and flow restitution were analyzed in a retrospective study. From January 1998 to December 2006, 24 adjuvant AVFs were constructed in autologous vein or composite pedal bypasses with low intraoperative bypass flow, poor status of the pedal artery, or during successful early bypass revision to prevent graft failure. All infrainguinal bypass operations were registered in a computerized database and prospectively followed. Pedal bypasses with adjunctive AVF were reviewed for fistula function, gr…

AdultMaleReoperationmedicine.medical_specialtyTime FactorsFistulamedicine.medical_treatmentArteriovenous fistulaRisk AssessmentAmputation SurgicalVeinsBlood Vessel Prosthesis ImplantationArteriovenous Shunt SurgicalIschemiaOcclusionmedicineHumansVascular PatencyTreatment Failurecardiovascular diseasesVascular PatencyAgedRetrospective StudiesAged 80 and overPeripheral Vascular DiseasesLegbusiness.industryPatient SelectionGraft Occlusion VascularRetrospective cohort studyGeneral MedicineMiddle AgedLimb Salvagemedicine.diseaseSurgerybody regionsmedicine.anatomical_structureAmputationBypass surgeryFemaleSurgeryRadiologyCardiology and Cardiovascular MedicinebusinessArteryAnnals of Vascular Surgery
researchProduct

Symptomatic Deep Femoral Artery Pseudoaneurysm Endovascular Exclusion. Case Report and Literature Review.

2017

Deep femoral artery pseudoaneurysms (DFAPs) are rare and generally occur after penetrating trauma or surgical procedures. A 36-year-old obese man presented with pain in correspondence of the anterior-lateral thigh after 6 months from gunshot wound. Duplex and computed tomography (CT) showed a bilobed right DFAP (maximal diameter 12.9 cm). The patient was managed urgently, under local anesthesia, by placement in the distal DFA of a Viabahn 8 × 100-mm stent graft (W L Gore & Associates, Inc). The postoperative course was uneventful, and the 24-month CT showed regular stent-graft patency and 20-mm DFAP shrinkage. The literature review reported 8 cases of DFAPs; of these 6 were managed by endo…

AdultMalemedicine.medical_specialtyComputed Tomography Angiographymedicine.medical_treatment030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolare030218 nuclear medicine & medical imaging03 medical and health sciencesPseudoaneurysmBlood Vessel Prosthesis Implantation0302 clinical medicineAneurysmBlood vessel prosthesisDeep Femoral ArteryMedicineVascular PatencyHumansVascular PatencyUltrasonography Doppler Duplexbusiness.industryEndovascular ProceduresStentGeneral Medicinemedicine.diseaseSurgeryBlood Vessel ProsthesisFemoral Arterysurgical procedures operativeTreatment OutcomeRegional Blood FlowSurgeryStentsWounds GunshotRadiologyGunshot woundbusinessCardiology and Cardiovascular MedicinePenetrating traumaAneurysm FalseAnnals of vascular surgery
researchProduct

New mesh shape and improved implantation procedure to simplify and standardize open ventral hernia repair: a preliminary report.

2010

Introduction Issues in ventral hernia repair are represented by the need for mesh fixation and how to assure a sufficient mesh overlap of the defect. Aiming to resolve these problems, this study describes a modified technique for ventral and incisional hernia repair based upon a newly developed mesh with a special design. This new type of implant allows broader coverage of the abdominal wall and results in tension- and fixation-free repair. Materials and methods A unique geometrically shaped mesh consisting of a large central body and radiating arms was used to repair ventral or incisional hernia. The mesh was intended not to be point-fixated. The friction of the straps passing through the …

AdultMalemedicine.medical_specialtyHerniaFrictionIncisional herniaAbdominal wallProsthesis ImplantationHematomaPreliminary reportProstheseRecurrencemedicineHumansSurgical Wound InfectionHerniaHerniorrhaphyFixation (histology)AgedSurgical fixation deviceVentral hernia repairbusiness.industryAbdominal WallImplantMiddle AgedSurgical Meshmedicine.diseaseHernia VentralSurgerySettore MED/18 - Chirurgia Generalemedicine.anatomical_structureSeromaVentralSurgeryFemaleImplantbusinessFollow-Up StudiesHernia : the journal of hernias and abdominal wall surgery
researchProduct

Tentacle-shaped mesh for fixation-free repair of umbilical hernias

2019

Purpose: Mesh fixation and broad overlap represent an open issue in umbilical hernia repair. A proprietary-designed implant with tentacle straps at its boundary has been developed to ensure a suture-free repair and a broader coverage of the abdominal wall. The study describes the results of umbilical hernia procedures carried out with the tentacle-shaped implant and the related surgical technique. Methods: A proprietary tentacle-shaped flat mesh having a central body with integrated radiating arms at its edge was used to repair large umbilical hernias in 62 patients. The implant was placed in preperitoneal sublay. The friction of the straps, crossing the abdominal wall thanks to a special n…

AdultMalemedicine.medical_specialtyHerniaHow-I-Do-Itmedicine.medical_treatmentNavelProsthesisProsthesis ImplantationAbdominal wallFixation freeRecurrenceUmbilicalmedicineHumansHerniaFreexationFriction forceHerniorrhaphyAgedUmbilicusTentacle meshbusiness.industryAbdominal WallSuture TechniquesProstheses and ImplantsMiddle AgedSurgical Meshmedicine.diseaseHernia repairUmbilical herniaSurgerySurgical meshmedicine.anatomical_structureHernia repairFemaleSurgeryImplantbusinessHernia UmbilicalHernia
researchProduct